  • Flow Rating: 100 Gallons Per Day (GPD) / 388 Litres Per Day (LPD)*
  • Model: T1812A100
  • 11.74 inches (298mm) x 1.75 inches (44.5mm)
  • Membrane Type: Residential Reverse Osmosis Element
  • Rated for a source water TDS of 500pm or lower
  • Stable Rejection Rating: 96%
  • R1 195,00
    i h

    100GPD American Made RO Membrane

    The Reverse Osmosis (RO) Membrane forms the heart of a Reverse Osmosis System. It consists of a semi-permeable membrane that allows water molecules to pass through but captures 99.8% of all other particles in the water. The RO Membrane removes bacteria, viruses, minerals, heavy metals, and pesticides from the water. 

    The 1812 RO Membranes are designed to work with low-pressure situations with small residential RO systems (such as under-the-counter ROs) or with small purification systems used for applications such as DI (Deionized) water, Laboratories, Hospitals, Battery water, aquariums, offices, ice makers, restaurants, etc. The Filmtec 1812 model membranes work most effectively with source waters that have a TDS of 500ppm or lower (<500ppm).

     

    Residential Reverse Osmosis Elements features:

    • Made in the USA in our ISO 9001:2008 Certified Facilities
    • NSF Certified in Select Models
    • Backed by our Experienced Technical Support Staff
    • High Quality for Consistent and Reliable Performance
    • Competitive Prices

        FilmTec Membranes are NSF Certified     DOW FilmTec Home RO Membranes are Made in USAISO Performance QualityWater Quality

     

    American Made 100GPD Membrane Specifications:

    • Average Permeated Flow (Product Water): 100GPD / 380LPD*
    • Stable Rejection Rate: 98%
    • Minimum Rejection Rate: 6%
    • Membrane Type Polyamide: Spiral-wound element with Thin-Film Composite

     

    Testing Conditions for Specification Rating: 

    Testing Pressure: 60psi (4 bar) 

    Testing Solution Temperature: 25°C

    Testing Solution Concentration (Softened Tap water) - 250ppm

    PH Value of Testing Solution: 7.5

    Recovery Rate of Single Element: 15%

     

    Keep in Mind

    The average permeated (product) water flow is based on test water consisting of 250ppm of only salt (NaCl) which is one of the easier minerals for the RO membrane to handle. Other elements such as hardness (lime, Calcium/Magnesium) are harder for the membranes to remove, and may reduce the average permeate rate of the RO membrane.

    Other elements such as source water pressure and the Total Dissolved Solids (TDS / Total Mineral Content) level can also have an influence on the permeate level produced by the membrane. Typically in real-world situations with municipal or non-municipal source water quality, you will not get the same quality and/or pressure as the "testing conditions" used to rate the membranes. So, in most applications, you will likely find that the actual permeate flow rate of the RO membrane is between 30 to 80% of what has been rated.

     

    Operating Limits for the Membrane:

    Maximum Operating Temperature: 113°F (45°C)

    Maximum Operating Pressure: 125 PSI (8 bar)

    Maximum Feed Flow Rate: 2.0 GPM (7.6 lpm)

    pH Range, Continuous Operation: 2 – 11

    pH Range, Short-Term Cleaning: (30 min.)b 1 – 12

    Maximum Feed Silt Density Index (SDI): 5

    Free Chlorine Tolerance: < 0.1 ppm

    *
    *
    *